SupportCustomer support service

News & Notice

[LiliF] AIV Fast & Multi qRT-PCR Series
Attached files Date 01-Nov-26 Hit 1072
VETERINARY DIAGNOSTICS • AIV SERIES APPROVED AS AN OFFICIAL DIAGNOSTIC KIT IN KOREA
iNtRON Biotechnology
Accelerated Avian Influenza Surveillance:
LiliF® AIV Fast & Multi qRT-PCR Series
Cut total turnaround time from over 2 hours down to ≤ 60 minutes. Combining universal Matrix (M) gene rapid screening with simultaneous 1-tube H5 / H7 / H9 multiplex subtyping under an identical, synchronized thermal cycling protocol. Validated with 100% clinical concordance across 550 poultry clinical specimens.
• Rapid Universal M Gene (≤ 60 min) • 1-Tube H5 / H7 / H9 Multiplex Subtyping • 100% Concordance on 550 Poultry Samples
≤ 60 min
Rapid Screening
2.2X faster than 130m assays
H5 / H7 / H9
1-Tube Multiplex
3-subtype differentiation
100.0%
Clinical Accuracy
Tested on 550 specimens
Korea Approved
Official Diagnostic Kit
Approved veterinary IVD
TOTAL DIAGNOSTIC PIPELINE • WORKFLOW HARMONIZATION
Seamless Field-to-Result Molecular Workflow
Standardized 3-step diagnostic pipeline for avian influenza surveillance from swab and fecal samples to definitive subtype identification.
STEP 01 • EXTRACTION ~15-20 min
High-Purity Viral RNA
Eliminate complex PCR inhibitors from tracheal/cloacal swabs and avian feces using proven spin-column or automated magnetic bead chemistry.
Validated Extraction Kits:
• Patho Gene-spin™ Kit (Spin Column)
• AutoXT PGS RNA Kit (Magnetic Beads)
STEP 02 • SCREENING ≤ 60 min
AIV M Real-time RT-PCR
Rapidly determine Type A Influenza presence. Highly conserved Matrix (M) gene target ensures universal detection of all circulating lineages.
• Regulatory: Approved as an official diagnostic kit in Korea
• Clinical Concordance: 100% (n=550)
STEP 03 • SUBTYPING ≤ 60 min
AIV 5/7/9 Multi qRT-PCR
Simultaneously differentiate H5, H7 (high pathogenicity suspects), and H9 in a single tube with zero optical crosstalk under synchronized cycling.
• Regulatory: Approved as an official diagnostic kit in Korea
• HA Multiplex: FAM (H5) / HEX (H7) / Cy5 (H9)
FLAGSHIP SCREENING • CONSERVED MATRIX (M) GENE
LiliF® AIV M Real-time RT-PCR Kit (Fast ver.)
FAST VER. • ≤ 60 MIN Officially Approved in Korea
Technical Highlights
Cat. No. IP15008 • Universal Type A Detection
Target Gene Influenza A Matrix (M) Gene (FAM Probe)
Run Duration ≤ 60 mins (Fast 40 Cycles)
Kit Controls Positive Control & Negative Control
Kit Format PreMix 20 μL tubes × 96 tests / kit
CLINICAL VALIDATION 100% Clinical Accuracy
550 Poultry Clinical Samples
Oropharyngeal & cloacal swabs, feces, tissues
100%
Sensitivity
330 / 330 Confirmed
100%
Specificity
220 / 220 Confirmed
Zero Cross-Reactivity: Clinically proven clearance against NDV, IBV, IBDV, and major bacterial pathogens (Salmonella spp., E. coli).
Total Evaluated: 550 / 550 Field Proven IVD • 100%
1-TUBE MULTIPLEX TYPING • HA SUBTYPE DIFFERENTIATION
LiliF® AIV 5/7/9 Multi qRT-PCR Kit
1-TUBE MULTIPLEX • ≤ 60 MIN Officially Approved in Korea
3-Subtype Optical Channels
Cat. No. IP15007 • Simultaneous Differentiation
H5 Subtype • FAM Channel
High Pathogenicity Suspect
H7 Subtype • HEX Channel
High Pathogenicity Suspect
H9 Subtype • Cy5 Channel
Endemic Lineage Monitoring
HA CONCORDANCE EVALUATION Official Validation
Zero Optical Cross-Talk
100% Concordance across all 3 HA targets
H5 Concordance 100% (110 / 110 detected)
H7 Concordance 100% (110 / 110 detected)
H9 Concordance 100% (110 / 110 detected)
Negative Controls 0% Cross-Reactivity (0 / 220)
Synchronized Protocol: Shares identical reverse transcription and thermal cycling parameters with Fast M kit for unified batch testing on a single 96-well instrument run.
SPECIFICATION MATRIX • ASSAY BENCHMARKS
Synchronized Cycling Protocol & Technical Specifications
Technical Parameter LiliF® AIV M Fast ver. (IP15008) LiliF® AIV 5/7/9 Multi (IP15007)
Diagnostic Purpose 1st-Line Universal Screening (Pos/Neg) 2nd-Line HA Subtyping (H5 / H7 / H9)
Target Gene Region Conserved Matrix (M) Gene Hemagglutinin (H5, H7, H9) Genes
Optical Channels FAM (Hydrolysis Probe) FAM (H5) / HEX (H7) / Cy5 (H9)
Turnaround Time ≤ 60 mins (Fast 40 Cycles) ≤ 60 mins (Synchronized Protocol)
Internal Quality Controls Positive Control & Negative Control Positive Control & Negative Control
Clinical Performance 100% Sensitivity • 100% Specificity 100% Concordance across all 3 subtypes
Regulatory Clearance Approved as an official diagnostic kit in Korea → Approved as an official diagnostic kit in Korea →
ORDERING INFORMATION
Complete AIV Real-Time Diagnostics & Extraction Series
Category Cat. No. Product Description (Click for details) Packaging
Fast & Multi
Flagship Reagents
IP15008 LiliF® AIV M Real-time RT-PCR Kit (Fast ver.)
60-minute rapid Matrix gene detection for universal screening
96 tests
IP15007 LiliF® AIV 5/7/9 Multi qRT-PCR Kit
Simultaneous 1-tube multiplex subtyping for H5, H7, and H9
48 / 96 tests
Standard Singleplex
Targeted Lineages
IP15004 LiliF® AIV M Real-time RT-PCR Kit 48 tests
IP15005 LiliF® AIV H5 Real-time RT-PCR Kit 48 tests
IP15006 LiliF® AIV H7 Real-time RT-PCR Kit 48 tests
Conventional
Multi-Tube PCR
IPC11009 LiliF® AIV Multi-tube RT-PCR Kit 12 tests
IPC12020 LiliF® AIV HA (1-16) Multi-tube RT-PCR Kit 6 tests
Patho™ RNA Extraction
Spin-Column & Automated
17154 Patho Gene-spin™ DNA/RNA Extraction Kit
Spin-column extraction for animal blood, swab, and tissue
50 preps
17168 AutoXT PGS DNA/RNA Extraction Kit (Pre-filled Cartridge) 48 / 96 preps
IMC-NC15PLUS Miracle-AutoXT Automated Extraction System 1 unit
iNtRON Biotechnology, Inc. • Molecular Diagnostics Division
13202, 137, Sagimakgol-ro, Jungwon-gu, Seongnam-si, Gyeonggi-do, Republic of Korea
Tel: +82-31-739-5741 | Fax: +82-31-739-5264 | Technical Support: tech@intronbio.com
Approved as an official diagnostic kit in Korea. Storage: -20 °C.
• © 2026 iNtRON Biotechnology, Inc. All rights reserved.

List

TOP