| Date | 01-Nov-26 | Hit | 1022 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PROBE qPCR TOTAL PLATFORM
Next-Generation Probe qPCR Master Mix Series:
RealMOD™ Probe M2 & R2 Series
Overcoming the critical diagnostic bottlenecks in clinical testing: complete amplicon carryover elimination (active heat-labile UDG), flawless amplification across extreme GC-rich templates (up to 75%), and rapid 5-channel multiplex kinetics under 50 minutes.
Carryover Clearance
99.99% Cleavage
Active Heat-Labile UDG Included
High-GC Tolerance
Up to 75% GC
Osmoprotectant Stabilized Buffer
Multiplex Speed
Under 50 Min 40-Cycles
5-Color Simultaneous Detection
SYSTEMATIC SCIENTIFIC MECHANISMS
How RealMOD™ Overcomes the 3 Critical Hurdles in Molecular Diagnostics
A side-by-side architectural breakdown of clinical diagnostic hurdles and their direct RealMOD™ biochemical solutions.
HURDLE 01
Carry-Over Contamination
99.99% Clearance • 0% Target Loss
CHALLENGE: Aerosol Amplicons & False Positives
Repeated qPCR cycles produce aerosol amplicons that contaminate equipment, triggering false positives in negative controls (NTC).
REALMOD SOLUTION: Active Heat-Labile UDG & dUTP
Pre-mixed UDG cleaves aerosol uracil-amplicons at 50°C, then irreversibly inactivates at 95°C so genuine target templates amplify with 100% fidelity.
Recommended Solution: RealMOD™ Probe M2 2X qPCR mix (Cat. 25360) & M2 2X qRT-PCR mix (Cat. 25361).
HURDLE 02
GC-Rich DNA Amplification Failure
Up to 75% GC • Zero Polymerase Stalling
CHALLENGE: Stem-Loop Structures & False Negatives
High GC templates exceeding 70% form dense stem-loops where conventional Taq stalls, causing late Ct calls or complete amplification dropout.
REALMOD SOLUTION: Osmoprotectant & Monoclonal Anti-Taq
Proprietary osmoprotectants lower G-C melting temperatures without destabilizing probes, ensuring smooth processivity and sharp Ct up to 75% GC.
Recommended Solution: RealMOD™ Probe M2 2X qPCR mix (Cat. 25360) & M2 2X qRT-PCR mix (Cat. 25361).
HURDLE 03
Multiplex Interference & Slow Kinetics
Up to 5-Plex Separation • Under 50 Min Cycling
CHALLENGE: Spectral Crosstalk & 85-Min Prolonged Lag
Syndromic panels suffer from fluorescent bleed-through and signal quenching, while 85+ min runs bottleneck diagnostic laboratory turnaround.
REALMOD SOLUTION: Multi-Dye Isolation & High-Speed Kinetics
Balanced ionic buffers equalize FAM, HEX, VIC, Cy5, and ROX channels. High-processivity polymerase finishes 40 cycles in under 50 minutes.
Recommended Solution: RealMOD™ Probe R2 2X qPCR mix (Cat. 25363) & R2 2X qRT-PCR mix (Cat. 25362).
ENGINE A SPOTLIGHT • HIGH-GC PRECISION
RealMOD™ Probe M2 Platform (with UDG)
Formulated to overcome Hurdle 1 (Carryover) and Hurdle 2 (GC-Rich Secondary Structures) for sensitive clinical pathogen diagnosis.
DNA • HIGH-GC qPCR
Cat. No. 25360
RealMOD™ Probe M2 2X qPCR mix (with UDG)
TaqMan® Probe DNA Master Mix with Active UDG System
Designed for cDNA, genomic DNA, and plasmid targets. Delivers robust amplification curves even when target regions exceed 65% GC content.
• Target Template: Genomic DNA, cDNA, and high-GC bacterial genes
• GC Tolerance: Flawless amplification across extreme > 75% GC clusters
• Primary Scope: M. tuberculosis, B. pertussis, high-GC pathogen IVD
1-STEP RNA • VIRAL DETECTION
Cat. No. 25361
RealMOD™ Probe M2 2X qRT-PCR mix (with UDG)
1-Step Reverse Transcription & Probe qPCR in Single Tube
Combines high-affinity M-MLV reverse transcriptase, hot-start Taq polymerase, and UDG. Tailored for sensitive single-copy viral RNA detection.
• Reagent Format: 2X All-in-One 1-Step RT-qPCR Premix
• Enzyme Chemistry: High-Activity RTase + Monoclonal Anti-Taq + UDG
• Key Applications: Respiratory RNA viruses, viral load monitoring
• Packaging Sizes: 100 / 500 / 1000 Reactions
ENGINE B SPOTLIGHT • SPEED & MULTIPLEX
RealMOD™ Probe R2 Platform (with UDG)
Formulated to overcome Hurdle 1 (Carryover) and Hurdle 3 (Multiplex Interference & Slow Runs) for high-throughput syndromic screening.
FAST qPCR • ≤ 50 MIN • 5-PLEX
Cat. No. 25363
RealMOD™ Probe R2 2X qPCR mix (with UDG)
Ultra-Fast DNA Amplification Across Up to 5 Channels
Accelerated elongation kinetics cut 40-cycle run times down to ≤ 50 minutes. Delivers zero spectral crosstalk across FAM, HEX, NED, Cy5, and ROX.
• Accelerated Speed: 40 cycles completed in under 50 minutes
• Multiplex Resolution: 5 channels (FAM, HEX, NED, Cy5, ROX) with zero crosstalk
• Primary Scope: High-throughput syndromic DNA screening & foodborne panels
FAST 1-STEP RNA • 5-PLEX
Cat. No. 25362
RealMOD™ Probe R2 2X qRT-PCR mix (with UDG)
Fast Synchronized 1-Step Multiplex RNA Master Mix
Integrates rapid reverse transcription and fast cycling kinetics in a single tube. Tailored for high-throughput respiratory and enteric RNA multi-pathogen panels.
• Rapid 1-Step RT-qPCR: Synchronized reverse transcription & fast cycling ≤ 50 min
• 5-Plex RNA Targets: Simultaneous detection across 5 discrete dye channels
• Primary Scope: Multi-respiratory (Flu/COVID/RSV) & enteric syndromic RNA panels
HEAD-TO-HEAD MATRIX • 4-PRODUCT COMPARISON
RealMOD™ Probe M2 & R2 Series: Comprehensive Feature Matrix
A single side-by-side technical breakdown across all 4 master mixes to select the ideal reagent for your diagnostic workflow.
TOTAL DIAGNOSTIC WORKFLOW
Integrated Molecular Pipeline: Extraction to Real-Time Quantification
STEP 01 • EXTRACTION
~15 - 20 min
Inhibitor-Free Nucleic Acids
Isolate high-integrity viral DNA/RNA without chemical inhibitors using manual silica spin-columns or automated pre-filled magnetic cartridges.
Validated Extraction Systems:
• Patho Gene-spin™ Kit (Spin Column)
• AutoXT PGS RNA Kit (Magnetic Cartridge)
STEP 02 • REACTION SETUP
Instant Hot-Start
2X Master Mix Assembly
Combine template with RealMOD™ 2X premix and TaqMan® primers/probes. Monoclonal Anti-Taq antibody blocks room-temperature mispriming.
Engine Match Selection:
• M2 Platform: High-GC templates & viral RNA
• R2 Platform: Multi-target syndromic panels
STEP 03 • QUANTITATIVE PCR
≤ 50 Min Run (R2)
UDG Cleansing & Detection
Heat-labile UDG enzymatically digests aerosol carryover amplicons prior to cycling. Thermocycling detects up to 5 fluorescent targets simultaneously.
Diagnostic Confidence:
• Single-copy analytical detection sensitivity
• 99.99% aerosol clearance for zero false-positives
ORDERING INFORMATION • COMPLETE DIAGNOSTIC SERIES
Order Specifications & Direct Product Links
iNtRON Biotechnology, Inc. • Molecular Diagnostics Division
13202, 137, Sagimakgol-ro, Jungwon-gu, Seongnam-si, Gyeonggi-do, Republic of Korea
Tel: +82-31-739-5741 | Fax: +82-31-739-5264 | Technical Support: tech@intronbio.com
© 2026 iNtRON Biotechnology, Inc. All rights reserved.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
