SupportCustomer support service

iNRON Magazine

Versatile SYBR Green Solution
Date 01-Aug-26 Hit 3116
iNtRON Biotechnology New Product Series

RealMOD™ Green T2 Series

Perform with Confidence — High-Performance Real-Time PCR Solutions Backed by Proven Data

qPCR Master Mix · DNA Targets qRT-PCR Master Mix · RNA Targets
92%
Target Specificity
Universal ROX
Compatible with any equipment
< 40 min
One-Step Total Runtime
99.99%
Carryover Prevention
1
Product Lineup at a Glance
RealMOD Green T2 2X qPCR mix Product Shot
DNA Target

RealMOD™ Green T² 2X qPCR mix

Cat. No. 25364 · 200 / 500 rxns
  • Optimized specifically for genomic DNA and cDNA templates.
  • Antibody-mediated hot-start Taq polymerase completely suppresses non-specific primer-dimer formation.
  • Delivers highly linear amplification sensitive down to single-digit target copies.
RealMOD Green T2 2X qRT-PCR mix Product Shot
RNA Target

RealMOD™ Green T² 2X qRT-PCR mix

Cat. No. 25365 · 100 / 300 rxns
  • Convenient one-tube, one-step workflow integrating reverse transcription and qPCR.
  • Pre-blended with 5X gDNA Eraser to completely eliminate genomic DNA contamination prior to run.
  • Integrated dUTP/UDG system effectively blocks PCR carryover contamination.
2
Advanced Chemistry & Core Formulations

The RealMOD™ Green T² Series incorporates an advanced chemistry matrix designed to eliminate sample dropouts at low template concentrations while suppressing non-specific, template-independent amplification. By integrating specialized enzyme stabilizers with a high-performance buffer system, this series guarantees absolute data integrity for critical research and molecular diagnostics.

Universal Instrument Compatibility

Pre-blended with a universal ROX passive reference dye. Performs seamlessly across low-ROX, high-ROX, and ROX-independent qPCR instruments without manual optimization.

Visual Verification Dye

Formulated with a non-interfering inert blue tracking dye for rapid visual confirmation of pipetting accuracy in multi-well plates, drastically reducing human loading errors.

Streamlined Two-Step Setup

Simply add primers and templates directly to the 2X master mix. Ready for immediate thermocycling, eliminating complex preparation protocols.

Workflow Comparison & Acceleration
1. Sample Prep
DNA/RNA Extraction
2. RT Reaction
3 Minutes (Fast RT)
3. Amplification
Fast qPCR Run
4. Analysis & Results
Total < 40 Minutes
Conventional Workflow: ~80+ Min   ➔   RealMOD™ Green T²: < 40 Min (Save over 1 hour of total runtime)
3
Data-Driven Performance Validation
RealMOD™ Green T² 2X qPCR mix
Performance Comparison vs. Competitor (GAPDH Target)
(A) Amplification Plot (FAM Channel)
qPCR Amplification Plot
(B) Melting Curve Profile
qPCR Melting Curve
Comparison of 10-fold serial dilutions (5 ng to 50 pg) of human gDNA template: RealMOD™ Green T² demonstrates significantly earlier Ct values, higher plateau fluorescence intensity, and cleaner single-target amplification profiles compared to Supplier A.
Linear Dynamic Range and Target Specificity
Standard Curve (Linearity)
qPCR Standard Curve
R² = 0.9994 | E = 99.5%
Target Specificity Comparison
qPCR Specificity Comparison
92% Specificity
Amplification Plot (CPIV cDNA)
qPCR Amplification Plot
Single-copy detection
RealMOD™ Green T² 2X qRT-PCR mix
Performance Comparison vs. Competitor (K562 Total RNA, GAPDH Target)
(A) Amplification Plot (FAM Channel)
qRT-PCR Amplification Plot
(B) Melting Curve Profile
qRT-PCR Melting Curve
Comparison of 10-fold serial dilutions (20 ng to 200 pg) of K562 cell total RNA: RealMOD™ Green T² 2X qRT-PCR Mix delivers earlier Ct values, superior final fluorescence yield, and high-specificity amplification curves compared to Supplier A.
Linear Dynamic Range & Carryover Contamination Control
Linear Dynamic Range for Viral Target (CPIV RNA)
Viral RNA Linear Dynamic Range
Dilution Range: 6 ng to 6 pg
Carryover Contamination Control (dUTP/UDG System)
UDG Contamination Prevention Chart
99.99% Prevention Efficiency
4
Ordering Information
Category Cat. No. Product Name Capacity
Green Type 25364 RealMOD™ Green T² 2X qPCR mix 200 / 500 rxns
25365 RealMOD™ Green T² 2X qRT-PCR mix 100 / 300 rxns
Probe Type 25363 RealMOD™ Probe R² 2X qPCR mix (with UDG) 200 / 500 / 1,000 rxns
25362 RealMOD™ Probe R² 2X qRT-PCR mix (with UDG) 100 / 500 / 1,000 rxns
25361 RealMOD™ Probe M² 2X qRT-PCR mix (with UDG) 100 / 500 / 1,000 rxns
25360 RealMOD™ Probe M² 2X qPCR mix (with UDG) 100 / 500 / 1,000 rxns
Extraction Kits
(Associated Products)
17045/17046 G-spin™ Total DNA Extraction Mini Kit 50 / 200 col.
17221 easy-spin™ Total RNA Extraction Kit 50 col.
17156 Patho Gene-spin™ HS DNA/RNA Extraction Kit 50 col.
iNtRON Biotechnology, Inc.
Global Leader in Molecular Diagnostics & Gene Extraction
Technical Support: tech@intronbio.com
Tel: 82-31-739-5741  |  Fax: 82-31-5264
© 2026 iNtRON Biotechnology, Inc. All rights reserved. For research use only. Not for diagnostic use.

List

TOP